IRIS 500 UNISCAN Ex IRIS500 UNISCAN Ex - Data sheet - DownloadIRIS500 UNISCAN Ex - Data sheet - Download ATEX - INERIS 03ATEX0175X - Certificate downloadATEX - INERIS 03ATEX0175X - Certificate download

Description

The IRIS uniscan Ex is a fail safe flame monitor and amplifier, mounted completely into one enclosure. Its purpose is to monitor gas or oil flames in process heaters, or the smaller utility boilers. The operating voltage range is 18 to 27VDC, so that losses or fluctuations in the voltage have no effect within these parameters. The flame on output is a 24VDC signal. As well as gain and drop out time adjustments a high band pass filter with four positions is provided for better discrimination. A DIN rail mounting power supply module, to provide a 24VDC output from a 115/230VAC input is available if required. A commissioning module is also available. It is battery powered, and is capable of powering the UNISCAN on the boiler front for approx. one hour. This enables an evaluation on performance, without the need for separate power supplies and wiring.

Characteristics

  • T. Amb.: -20°C / +70°C
  • Degree of protection: IP66
  • Power supply: 24Vdc from flame signal amplifier
  • Self checking by electronic switching
  • Fail safe
  • Waves spectrum detect: 750-1900nm
  • Output 1 normal open volt powers 24Vdc contact for flame on (SPST)
  • Electrical connection: 3/4" NPTF
  • Connection to the burner: 1"NPTF
  • Flame drop out time selectable to 1-2 or 3 seconds
  • Purge air connection: 1/2" NPTF
  • Purge air flow required: approx 1,7cbm/h